Wiring the Operator for Required Handing (Magic-Force Operators)
NOTE: Operator cams are factory-set for right hand operaon.
Refer to Figure 4, and DETERMINE door handing.
CONNECT operator harness from close speed module to control box motor 1 and motor 2 connectors,
if applicable
Wiring the Power Close Speed Module
Refer to Aachment 2 and CONNECT the Power Close Speed Module.
Wiring the “ON/OFF/HOLD OPEN” Switch and Power Switch
Refer to Aachment 2, and CONNECT ON/OFF/HOLD OPEN switch wiring as follows:
TB2 Terminal Connection Switch Wire Color
1 Hold Open Yellow
2 Common Orange
3 Automac On Violet
SET POWER switch to OFF.
CONNECT POWER switch harness 516857-1 to power harness 415000.
CONNECT line connect harness 412544 to power harness 415000.
Wiring the Door Activation or Safety Device
NOTE: Aachments 2, 3, and 4 illustrate typical wiring for various devices. Though the specic device may not be
shown, this aachment can be used as a general guide. Specic wiring instrucons from the manufacturer must
also be consulted.
Refer to Aachments 2, 3, 4 and applicable manufacturers instrucons, and CONNECT door acvaon
or safety device.
LEFT HAND
DOOR
OPENING
MOTION
RIGHT HAND
Figure 4. Door Handing