iQ Control Box
10.18.2019
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204143 REV 5 11
Copyright 2019, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
Wiring Swing Guard T
Caution: Do not connect Swing Guard T Daughter Board or Sensors unl control box is fully tuned.
NOTE: Select Swing Guard T when in Step 9 of Table 1 if tuning with pushbuons, even though Swing Guard T
has not been connected at this me. If tuning with ‘Hand Held Device’, select Swing Guard T for Safety Logic.
1. Set DIP switches on the Swing Guard T Controller so that the sensor is always enabled (DIP switch 3
DOWN for auto).
2. To perform a first learn on the Swing Guard T system, Manual Mode Sensor Override must be set to OFF or
the door will not open and the learn will not complete. Once the learn is complete, set Manual Mode Sensor
Override to ON.
3. Wire SU100 into TB4.
NOTE: Do not use purple wires on Swing Guard T Controller wire harness.
TB1 Terminal Connection Swing Guard T Wire Color
1 (+) Power for Swing Guard T Red
2 Serial Communicaon Green
3 Serial Communicaon White
4 (-) Power for Swing Guard T Black
NOTE: Refer to the Swing Guard T installaon manual for Sensor Head mounng locaons, DIP switch
sengs, angle adjustments and roung of wire harnesses.
Wiring Bodyguard-T
The Bodyguard-T does not require a lockout relay for use with the iQ control box. The iQ control box generates the
data signals for door open, closing, and closed posions. Refer to Aachment 2, 3 , or 4, as applicable for wiring
connecons. Program the Bodyguard-T Relay Output to #1.
Wiring Superscan-T
Refer to Aachment 2, 3 , or 4 as applicable for wiring connecons.
Wiring Holding Beam
The Holding Beam input is used in applicaons when there is a rail-mounted holding beam. When the door is
closing and the beam is obstructed, the door will not open unl the door is completely closed and the header-
mounted sensor becomes acve. When the door is open and the beam is obstructed, the door will remain open.
Refer to Aachment 2, 3 , or 4 as applicable for wiring connecons.
Wiring Other Sensors
Refer to Aachment 2, 3, 4 or 5 as applicable for wiring connecons.