iQ Control Box
01.25.2019
1.800.7.ACCESS • www.stanleyaccess.com • Document # 204144 REV B 11
Copyright 2019, Stanley Access Technologies, LLC. All rights reserved. Reproduction
in whole or in part without the express written permission of Stanley is prohibited.
Index Min
Value
Max Value Description Defaults
Single Dual
15 1 10 Open
Braking
The Open Braking parameter adjusts
how quickly the door slows down prior
to check speed.
Increasing this parameter increases
braking power.
8 8
16 0 40 Close
Acceleraon
Close Acceleraon aects the rate at
which the door gets to its target speed.
This parameter is used when the door is
lagging close speed, close startup torque
and close startup length should be
invesgated prior to increasing.
This parameter aects all close moon
speeds: close speed, close check speed,
close learn speed, as well as close
braking.
20 20
17 1 10 Close
Braking
The Close Braking parameter adjusts
how quickly the door slows down prior
to check speed.
Increasing this parameter increases
braking power.
4 2
18 0 6 Delayed Egress Special Locking Applicaon. See the
Delay Egress Instrucon Manual for use.
00 = O
01 = 15 sec delay 1 second nuisance
02 = 30 sec delay 1 second nuisance
03 = 15 sec delay 2 second nuisance
04 = 30 sec delay 2 second nuisance
05 = 15 sec delay 3 second nuisance
06 = 30 sec delay 3 second nuisance
0 0
19 0 5 Safety Logic 00 - Monitored 2 Sensors: Threshold
zone control (the threshold zone
is enabled and disabled by the iQ).
1 - Monitored 4 Sensors: Threshold
zone control (the threshold zone is
enabled and disabled by the iQ).
2 - Monitored StanGuard™: (not
recommended for Telescopic doors).
3 - Monitored 2 sensors.
4 - Non-monitored sensors.
5 - Monitored 4 sensors.
2 2
Table 3. Settings (continued)
Table 3 Settings continued next page.