– 83 –
APPENDIX
3) 2-character set codes
Control codes
Code HEX Format HEX
NUL 00H %@ 25H 40H
SOH 01H %A 25H 41H
STX 02H %B 25H 42H
ETX 03H %C 25H 43H
EOT 04H %D 25H 44H
ENQ 05H %E 25H 45H
ACK 06H %F 25H 46H
BEL 07H %G 25H 47H
BS 08H %H 25H 48H
HT 09H %I 25H 49H
LF 0AH %J 25H 4AH
VT 0BH %K 25H 4BH
FF 0CH %L 25H 4CH
CR 0DH %M 25H 4DH
Special code
Code HEX Format HEX
% 25H %0 25H 30H
Function codes
Code HEX Format HEX
FNC1 %1 25H 31H
FNC2 %2 25H 32H
FNC3 %3 25H 33H
FNC4 %4 25H 34H
Start codes
Code HEX Format HEX
START A
%6 25H 36H
START B
%7 25H 37H
START C
%8 25H 38 H
SO 0EH %N 25H 4EH
SI 0FH %O 25H 4FH
DLE 10H %P 25H 50H
DC1 11H %Q 25H 51H
DC2 12H %R 25H 52H
DC3 13H %S 25H 53H
DC4 14H %T 25H 54H
NAK 15H %U 25H 55H
SYN 16H %V 25H 56H
ETB 17H %W 25H 57H
CAN 18H %X 25H 58H
EM 19H %Y 25H 59H
SUB 1AH %Z 25H 5AH
ESC 1BH %[ 25H 5BH
FS 1CH %× 25H 5CH
GS 1DH %] 25H 5DH
RS 1EH %^ 25H 5EH
US 1FH % 25H 5FH
DEL 7FH %5 25H 35H
EXAMPLE Bar code string number 00, starting position of bar code (X, Y)
= 15 mm, 5 mm, use Mode 1 of CODE128, Bar code height 15
mm, data: 1213477657, and CR (carriage return)
LPRINT CHR$(&H1B);“PB00;0150,0050,1,7,0150”;
CHR$(&H0A);CHR$(&H00);
LPRINT CHR$(&H1B);“RB00;1213477657%M”;
CHR$(&H0A);CHR$(&H00);