EasyManua.ls Logo

Star Micronics TSP600 Series - Page 115

Star Micronics TSP600 Series
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
112
APPENDIX
The factory settings of DIP switch are all on, except for switches 7 and 8.
DIP-SW 3
Switch
Function ON OFF
3-1
Baud Rate See table below
3-2
3-3 Data Length 8 bits 7 bits
3-4 Parity Check Disabled Enabled
3-5 Parity Odd Even
3-6 Handshake DTR/DSR XON/XOFF
3-7 Pin #6 (DSR) reset signal Valid Invalid
3-8 Pin #25 (INIT) reset signal Valid Invalid
Baud Rate Switch 3-1 Switch 3-2
4800BPS OFF ON
9600BPS ON ON
19200BPS ON OFF
ON
OFF
The following is the procedure for changing the settings on DIP switch No. 3.
1. Turn off the printer and all components connected to it.
2. Remove the 2 screws.
3. Remove the serial interface board unit.
4. Change the setting of the DIP switches.
5. Replace the serial interface board unit.
Then secure it with the screws.
6. Turn on the printer and all components connected to it.
No. 1
DIP-SW3
2 3 4 5 6 7 8

Table of Contents

Other manuals for Star Micronics TSP600 Series

Related product manuals