15-10
15.3.6 Memory Switch F (MSWF)
Bit Function 0 1 STAR ESC/POS Note
F Continuous <LF> Cut
Conversion Function
(See Table Below) ○ ○
*2
E Continuous <LF> Cut
Conversion Function
(See Table Below) ○ ○
*2
D Continuous <LF> Cut
Conversion Function
(See Table Below) ○ ○
*2
C Continuous <LF> Cut
Conversion Function
(See Table Below) ○ ○
*2
B Cut Conversion Function
Cutting Specifications
Partial Cut Full Cut ○ ○
*3
A
9
8
7
6
5
4
3
2
1
0
[*2] MSWF-C, D, E, F Continuous <LF> Cut Conversion Function
N1 MSW F-F MSWF-E MSWF-D MSWF-C Function
“0” 0 0 0 0 Continuous <LF> Cut Conversion Function
Disabled
“1” 0 0 0 1 Continuous <LF>2
nd
Time → Cut Converted
“2” 0 0 1 0 Continuous <LF>3
rd
Time → Cut Converted
“3” 0 0 1 1 Continuous <LF>4
th
Time → Cut Converted
“4” 0 1 0 0 Continuous <LF>5
th
Time → Cut Converted
“5” 0 1 0 1 Continuous <LF>6
th
Time → Cut Converted
“6” 0 1 1 0 Continuous <LF>7
th
Time → Cut Converted
“7” 0 1 1 1 Continuous <LF>8
th
Time → Cut Converted
“8” 1 0 0 0 Continuous <LF>9
th
Time → Cut Converted
“9” 1 0 0 1 Continuous <LF>10
th
Time → Cut Converted
“10” 1 0 1 0 Continuous <LF>11
th
Time → Cut Converted
“11” 1 0 1 1 Continuous <LF>12
th
Time → Cut Converted
“12” 1 1 0 0 Continuous <LF>13
th
Time → Cut Converted
“13” 1 1 0 1 Continuous <LF>14
th
Time → Cut Converted
“14” 1 1 1 0 Continuous <LF>15
th
Time → Cut Converted
“15” 1 1 1 1 Continuous <LF>16
th
Time → Cut Converted
This function is disabled when executing Auto Logo, initialization macro, macro, and ESC/POS page mode.
[*3] MSWF-B Cut Conversion Function Cutting Specifications
MSWF-B = 0 (Partial Cut) MSWF-B = 1 (Full Cut)
STAR ESC d n (n=3) ESC d n (n=2)
ESC/PO
S
To save print data, executes priting
+
GS V m n (m=66, n=0)
To save print data, executes printing
+
GS V m n (m=65, n=0)