TUP500 Series Product Specifications 3-8
(5) Recommended Thermal Paper and Setting Print Density: See the table below.
Manufacturer Product Name Quality Characteristics and Use
Paper Thickness
μm
Value
N
Mitsubishi
Paper Mills
Limited
P220AG Normal Type 65 3 (Default)
HP220A Long-storage Type 65 3 (Default)
HP220AB-1 Long-storage Type 75 3 (Default)
P220AGB Normal Type (For Cards and Tickets) 80 2
P220AB Normal Type (For Cards and Tickets) 85 2
PB670/PB770 2-Color Type (Red/Black, Blue/
Black)
75 3 (Default)
Oji Paper
Company
PD450 Normal Type 60 2
PD150R Normal Type 75 3 (Default)
PD160R Long-storage Type 65/75 2
PD750R/PD700R 2-Color Type (Red/Black, Blue/
Black)
75 3 (Default)
KSP P320RB/P320BB 2-Color Type (Red/Black, Blue/
Black)
65 3 (Default)
Nippon Paper
Industries
TF50KS-E2D Normal Type 65 3 (Default)
Note:
1. Print density settings must be changed according to the type and thickness of the paper.
2. Memory Switch 2: Change print density setting, or the density setting using the print den-
sity setting command <ESC> <RS> ‘d’ n.
3. There is the possibility that adequate reading results of bar codes or characters may not
be attained because of the scanner, paper type of print density. If so, evaluate your scan-
ner in advance.
4. To use 2-color type thermal paper, print in the dedicated 2-color print mode.
(6) Adjusting the Head Position: See the table below.
The printer requires that the head position be adjusted according to the thickness of the
paper to be used to ensure high quality printing.
To adjust the head position, change the position of the head adjust lever.
See the table below to set to the optimum lever position.
Notes:
1. Depending on the type of paper used, the desired print quality may not be attained even
if the head position is adjusted as described below. In such cases, try two head position
settings and use with the position setting that gives you good results. Change the print
density as required.
Fig. 3.3.1.6A . N orm al P o sition
Fig. 3.3.1.6B . Thick Paper Position
Head Adjust Lever
Head Adjust Lever