– 46 –
11-3. USB Interface Model
ON ON
OFF OFF
DIP-SW 1
Switch Function ON OFF
1-1 Command emulation (Ster Line mode) Always ON
1-2 Should not be changed (Should be set to on)
1-3 Should not be changed (Should be set to on)
1-4 Sensor adjustment Invalid Valid
1-5 USB mode Printer class Vendor class
1-6 Handshaking conditions (conditions for
BUSY)
Offline or receive
buffer full
Receive buffer full
1-7 Automatic status back function *1 Invalid Valid
1-8 Should not be changed (Should be set to on)
1-9 Low-power consumption mode Invalid Valid
1-10 Should not be changed (Should be set to on)
*1 Automatic status back function is disabled when USB mode is Printer Class (switch 1-5 =
ON).
The factory settings of DIP switch are all on.
DIP-SW 2
Switch Function ON OFF
2-1~2-4 Always ON Should be set to on
The factory settings of DIP switch are all on.
No. 1 2 3 4 5 6 7 8 No. 1 2 3 4
9 10