EasyManua.ls Logo

Status Instruments DM640X Series - Page 2

Default Icon
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 2 of 4
5.0 MAINTENANCE
Warning
The DM640X contains no user serviceable parts apart from the battery.
The DM640X must not be configured in the hazardous area.
No attempt should be made to repair the DM640X, all units must be returned
to the manufacturer for repair or replacement. Attempted repair or service
may invalidate the explosive protection feature of this equipment.
If re-calibration is required please contact your supplier for further
information. Under certain circumstances, it may be possible to re-calibrate
the device while it is still out in an application.
6.0 ATEX CERTIFICATE
The DM640X have been issued with a EC- type examination certificate, confirming
compliance with the European ATEX directive 94/9/EC for :-
Classification II 1 G D EEx ia IIC T4
The unit bears the Community Mark and subject to local codes of practice, may be
installed in any of the European Economic Area (EEA) Members countries. The
equipment must be installed and maintained in accordance with local requirements for
electrical equipment for use in potentially explosive atmospheres, eg EN60079-14 &
EN60079-17. This instruction sheet describes installation, which confirms with
BSEN60079-14 & BS EN60079-17. When designing systems outside the UK, the local
code of practice should be consulted.
When installed correctly the DM640X series may be used in the following
areas :-
ZONE HAZARDOUS AREA CHARACTERISTIC
worst case
GAS DUST
0 20 Hazard Continuously present
1 21 Hazard likely to occur in normal use
2 22 Hazard not likely to occur and if it does, only for a short time.
Be used in gas groups :-
Group A propane
Group B ethylene
Group C hydrogen
Allowable temperature class
T4 135°C Tamb -20 to 50°C
6.1 ATEX Mark
The DM640X/P and DM640X/TC product labels carry the following information:-
Front Panel Label
Manufacturer Status instruments Ltd
Type DM640X/P DM640X/TC
Explosive protection mark
CE mark
Approval II 1 G D EEx ia IIC T4
Certification reference TRL06ATEX11100X
Internal Label
Serial Number (includes date code)
Type DM640X/TC or DM640X/P
Manufacturer information www.statinst.com
Environmental protection: The equipment must be housed in the SCH4
series of enclosure offering protection to IP67. The enclosure must be
suitable for the atmosphere and environment in which it is installed.
6.2 SPECIALCONDITIONS FOR SAFE USE
ELECTROSTATIC HAZARD. DO NOT CHARGE BY RUBBING OR CLEANING
WITH SOLVENTS.
DO NOT CHANGE BATTERY IN THE HAZARDOUS AREA.
DM640XTC ONLY SUITABLE FOR CONNECTION TO TYPE K,T,J,R,S,N,E,F
THERMOCOUPLES, THEY SHALL CONFORM TO THE REQUIREMENTS FOR
SIMPLE APPARATUS AS DEFINED IN CLAUSE 5.4 OF EN 50020:2002 AND
THE INPUT PARAMETERS MARKED ON THIS UNIT.
DM640XP ONLY SUITABLE FOR CONNECTION TO RESISTANCE
TEMPERATURE SENSORS TYPES PT100 , NI120. THEY SHALL CONFORM
TO THE REQUIREMENTS FOR SIMPLE APPARATUS AS DEFINED IN
CLAUSE 5.4 OF EN 50020:2002 AND THE INPUT PARAMETERS MARKED ON
THIS UNIT.
USE ONLY TEKCELL SB-AA11 BATTERY, PART NO 28-302-0036-00.
THE UNIT SHALL BE CLEANED REGULARLY TO PREVENT THE BUILD UP
OF EXCESSIVE DUST LAYERS.
6.3 ENCLOSURE MATERIALS
SCH4 enclosure material ABS.
SCH4 cap Polycarbonate.
O ring seals NBR Acrylonitrile / Butadiene Rubber (Black).
Fig. 1 Front Panel label
Fig 2 Rear view
0891
DM640 X /TC
!
www .statu s.co. uk
S/No 000000 - 0101
-
+
1
1
2
4
3
+
-
6
BATTERY COVER REMOVED
BAT TERY COVER FITTE D