Steinberg Systems SBS-PW-402C - Common Troubleshooting; Troubleshooting Guide

Steinberg Systems SBS-PW-402C
17 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Trouble Instruction Possible Reason Remedy
AC lamp is not
glowing
Power may
not be con-
nected
The mains plug may
be disconnected
The power cable is
damaged
Insert the power
plug or replace it
if damaged
Change the pow-
er cable
Scale is not
turning on with
battery
There is no
DC power
supply to the
Scale
The storage batte-
ry is damaged
The battery con-
nection are not
proper
Replace the
battery of the
similar model
Ensure that con-
nections are in
good condition
Over voltage
LED glows,
Alarms and
automatically
turn off
Over Voltage Battery is in use for too
long time
Charge the
battery
Change the
battery is found
damaged
Weight reading
is unstable
Over voltage
or affected by
moisture
Insufcient voltage
OR use of battery is
prolonged even after
the warning alarm OR
too much humidity in
surrounding
Charge the battery
for at least 10 hours;
Or clean the Mother
PCB for drying
Common Trouble Shooting
Following chart will show you the common trouble shooting.