5. BEFORE FIRST USE
DANGER! Risk of injury due to electric shock.
Warning! Do not plug in before installation is fully completed!
NOTE: The intake line must be a vacuum-resistant hose or pipe.
Preparing the intake line
B
• As a basic principle, we recommend using:
- A preliminary filter, in order to avoid unnecessary damage to the pump as a result of stones
and solid foreign bodies (Fig.
A
).
- A suction-hose set with suction hose and an intake valve with a strainer (in order to prevent
long priming periods) (Fig.
B
).
A
If you cannot obtain a suction-hose set like above, please purchase (Fig.
C
):
- an 25 mm (1”) intake hose
9
- an intake valve with a strainer
10
- 2 hose clamps
11
and 2 standard adapters
12
(1 for the intake line, 1 for discharge line)
and assemble the suction-hose set yourself using a standard adapter
12
and a clamp
11
.
9
10
11
12
C
123
EN
20151214 SPECIFICATIONS 1300 WT 50 SM5I-3.indd 123 14/12/15 12:19