EasyManua.ls Logo

STIEBEL ELTRON DCE-C 10/12 Trend - INSTALLATION - Specification; 16. Specification; 16.1 Dimensions and connections

STIEBEL ELTRON DCE-C 10/12 Trend
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INSTALLATION

ENGLISH
www.stiebel-eltron.com DCE-C Trend | 13
Alternative connection options
100
c01c06
b02
72
330
b02
b02
69
35
336
b02
b03
30
61
15
b03
D0000073720
DCE-C Trend
b02 Entry for electrical cables I Finished walls
b03 Entry for electrical cables II Unfinished walls
c01 Cold water inlet Male thread G 1/2 A
c06 DHW outlet Male thread G 1/2 A
16.2 Wiring diagram
DCE-C Trend
L L
2/GRD ~ 220 / 230V
L N
1/N/PE ~ 220 / 230V
N
L
L
L
D0000077991
1
3
4
2
1 Power PCB with integral safety switch
2 Bare wire heating system
3 High limit safety cut-out
4 Mains terminal
16.3 DHW output
The DHW output is subject to the connected power supply, the
appliance's connected load and the cold water inlet temperature.
The rated voltage and rated output can be found on the type plate.
Connected load in kW 
Rated voltage Cold water inlet temperature
     
6.0 2.6 3.1 3.7 4.8
8.0 3.5 4.1 5.0 6.3
6.6 2.9 3.4 4.1 5.2
8.7 3.8 4.4 5.4 6.9
10.0 4.3 5.1 6.2 7.9
12.0 5.2 6.1 7.5 9.5
11.0 4.8 5.6 6.8 8.7
13.1 5.7 6.7 8.1 10.4
Connected load in kW 
Rated voltage Cold water inlet temperature
     
6.0 1.9 2.1 2.4 2.9
8.0 2.5 2.9 3.3 3.8
6.6 2.1 2.4 2.7 3.1
8.7 2.8 3.1 3.6 4.1
10.0 3.2 3.6 4.1 4.8
12.0 3.8 4.3 4.9 5.7
11.0 3.5 3.9 4.5 5.2
13.1 4.2 4.7 5.3 6.2
16.4 Application areas/ conversion table
Electrical resistivity and electrical conductivity.
Standard specifica-



Resis-
tivity
ρ≥
Conductivity σ
Resis-
tivity
ρ≥
Conductivity σ
Resis-
tivity
ρ≥
Conductivity σ
Ωcm mS/m μS/cm Ωcm mS/m μS/cm Ωcm mS/m μS/cm
1100 91 910 970 103 1031 895 112 1117
16.5 Pressure drop
Taps

Mono lever mixer tap, approx. MPa 0.04 - 0.08
Thermostatic valve, approx. MPa 0.03 - 0.05
Shower head, approx. MPa 0.03 - 0.15
Sizing the pipework
When calculating the size of the pipework, an appliance pressure
drop of 0.1MPa is recommended.
16.6 Fault conditions
In the event of a fault, loads up to 80°C at a pressure of 1.0MPa
can occur briefly in the installation.

Table of Contents

Related product manuals