www.stiebel-eltron.com DEL SL electronic LCD | 31
INSTALLATION
Installation
Adjustable connected load
With the
DEL 18/21/24 SL , 3 connected load stages can be select-
ed. The middle load is preset. With a different connected load,
proceed as follows:
D0000047341
Select the connected load you require (see chapter "Specifi-
cation/ Data table").
Plug in the coding card according to the selected connected
load.
Change the type plate. Tick the selected connected load.
Please use a ballpoint pen to do this.
10.2 Completing the installation
Open the 3-way ball shut-off valve.
26�02�02�1102�
Fit the lower part of the back panel. Ensure that it clicks into
place.
Align the mounted appliance by loosening the fixing toggle,
aligning the electrical connection and back panel, and then
re-tightening the fixing toggle. If the back panel of the appli-
ance is not flush, the appliance can be secured at the bottom
with an additional screw.
10.3 Installation options
- Electrical connection from above on unfinished walls
- Electrical connection on finished walls
- Large cross-section for electrical connection from below
- Connecting a load shedding relay
- Water installation on finished walls
- Water installation for finished walls with solder / compres-
sion fitting
- Water installation on finished walls, fitting the appliance
cover
- Installation of lower back panel with threaded fitting on fin-
ished walls
- Use of existing wall mounting bracket when replacing an
appliance
- Installation with offset tiles
- Pivoting appliance cover
- Operation with preheated water
- Anti-scalding protection/ temperature limit
Electrical connection from above on unfinished walls
26�02�02�1123�
Cut open the cable grommet for the power cable.
Push down the locking hook to secure the mains terminal.
Pull out the mains terminal.
Reposition the mains terminal in the appliance from the
bottom to the top and secure the mains terminal by sliding it
under the locking hook.
Route the control wires below the wire guide.