To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGLISH
www.stiebel-eltron.com HDB-E Si | 23
INSTALLATION
Installation
26�02�02�1101
Press the two locking hooks and remove the lower part of
the back panel towards the front.
26�02�02�0810�
Mark out the holes for drilling using the installation template.
Drill the holes and secure the mounting bracket with
2screws and 2rawl plugs (screws and rawl plugs are not
part of the standard delivery).
Note
If you are installing the appliance with flexible water con-
nections. secure the back panel with a screw.
Fit the mounting bracket.
160
≥ 30
26�02�02�0887
Prepare the power cable.
Making the water connection
!
Material damage
Carry out all water connection and installation work in
accordance with regulations.
12
D0000053319
Seal and insert the twin nipples.
1 2
26�02�02�0799
1 DHW tee
2 Cross-piece
Secure the tee and cross-piece, with a flat gasket each, to the
twin nipples.
Fitting the strainer
!
Material damage
The strainer must be fitted for the appliance to function.
When replacing the appliance. check that the strain-
er is present.
26�02�02�0856
Fit the strainer provided in the cold water inlet of the
appliance.
Installing the DMB flow limiter
26�02�02�0857
Install the flow limiter provided in the cold water inlet of the
appliance.