Repair instructions
HPG-I 04-06-08-12-15 S-CS-DS-DCS
Premium
TQR
Page 32 from 48
D0000095883-c
Message code
Reason for the message
Possible remedy
2-0073
Inverter main fault: Motor overspeed.
Inverter error
2-0074
Inverter secondary fault: DC link
undervoltage.
Inverter error
2-0075
Inverter secondary fault: Torque limit
reached.
Inverter error
2-0076
Inverter secondary error:
Modbus communication
disturbed.
Inverter error
2-0077
Inverter secondary fault: Compressor
scroll overtemperature.
Inverter error
2-0078
Inverter secondary fault: Compressor
motor overtemperature.
Inverter error
2-0079
Inverter secondary fault: circuit
overtemperature.
Inverter error
2-0080
Inverter secondary fault: Inverter IGBT's
overtemperature.
Inverter error
2-0081
Inverter secondary fault: Inverter PFC
IGBT's overtemperature.
Inverter error
2-0084
Inverter secondary fault: Temperature
differences between the three inverter
IGBTs.
Inverter error
2-0085
Inverter secondary error: Temperature
differences between the three inverter
PFC IGBTs.
Inverter error
2-0091
Inverter secondary error: communication
between analogue-digital converter and
Secondary processor disturbed.
Inverter error
2-0093
Inverter secondary error: Low-relevant
communication objects between IWS and
inverter were not correctly transmitted
several times.
Inverter error Check the wiring and the
associated connectors, replace if defective.
2-0095
Inverter main error: Collective error 1
Inverter error
2-0096
Inverter main error: Collective error 2
Inverter error
2-0097
Inverter secondary error: Collective error
1
Inverter error
2-0098
Inverter secondary error: Collective error
2
Inverter error
2-0100
Low pressure falls below SOA ND limit
for unacceptable time period.
Refrigerant circuit cannot shift operating
conditions into SOA range of compressor.
2-0101
Low pressure exceeds SOA ND limit for
unacceptable time period.
Refrigerant circuit cannot shift operating
conditions into SOA range of compressor.
2-0102
SOA Range overrun.
Refrigerant circuit cannot shift operating
conditions into SOA range of compressor.
2-0103
High pressure falls below SOA HD limit
for unacceptable time period.
Refrigerant circuit cannot shift operating
conditions into SOA range of compressor.
2-0104
High pressure falls below SOA ND limit
for unacceptable time period.
Refrigerant circuit cannot shift operating
conditions into SOA range of compressor.
2-0105
SOA Range overrun.
Refrigerant circuit cannot shift operating
conditions into SOA range of compressor.
2-0135
Inverter main fault: Input current
limitation.
Inverter error
2-0136
Inverter main fault: Output current
limitation.
Inverter error
2-0137
Inverter main fault: Phase loss.
Inverter error
2-0138
Inverter main fault: Power module.
Inverter error