OPERATION
Menu structure
www.stiebel-eltron.com  LWZ304-404 SOL | 21
Menu item/parameter Options Direct Unit Dis-
play 
only
Min. Max. Standard
LWZ 304 SOL 
[  L W Z 4 0 4 S O L  ]
Energy sav-
ing recom-
mendation
System 
value
PROGRAMS
HEATING PROGRAM
 HEATING CIRCUIT 1
 MONDAY Time period1| Time peri-
od2| Time period3
 TUESDAY Time period1| Time peri-
od2| Time period3
 WEDNESDAY Time period1| Time peri-
od2| Time period3
 THURSDAY Time period1| Time peri-
od2| Time period3
 FRIDAY Time period1| Time peri-
od2| Time period3
 SATURDAY Time period1| Time peri-
od2| Time period3
 SUNDAY Time period1| Time peri-
od2| Time period3
 MON - FRI Time period1| Time peri-
od2| Time period3
 SAT - SUN Time period1| Time peri-
od2| Time period3
 MON - SUN Time period1| Time peri-
od2| Time period3
 HEATING CIRCUIT 2 See HEATING CIRCUIT 1
DHW PROGRAM See HEATING CIRCUIT 1
FAN PROGRAM See HEATING CIRCUIT 1
HOLIDAY PROGRAM
 HOLS BEGINNING
 DAY 1 31 1
 MONTH 1 12 1
 YEAR 0 99 11
 HOUR 0 23
 MINUTE 0 59
 HOLIDAYS ENDING
 DAY 1 31 1
 MONTH 1 12 1
 YEAR 0 99 11
 HOUR 0 23 0
 MINUTE 0 59
PARTY PROGRAM
 START 00:00 23:45
 END 00:00 23:45
STANDARD SETTING
 MAX. ADVANCE 59 min 0 300 0
SETTINGS
HEATING
 ROOM TEMPERATURES HC1
 ROOM TEMPERATURE DAY HC1 01 °C 10 30 21 20
 ROOM TEMP. NIGHT HC1 02 °C 10 30 21 20
 ROOM TEMP. STANDBY HC1 03 °C 10 30 10
 MANUAL SET HC1 10 °C 10 65 35
 ROOM TEMPERATURE HC1 °C X
 ROOM TEMPERATURES HC2
 ROOM TEMPERATURE DAY HC2 °C 10 30 21 20
 ROOM TEMP. NIGHT HC2 °C 10 30 21 20
 ROOM TEMP. STANDBY HC2 °C 10 30 10
 MANUAL SET HC2 °C 10 65 35
 ROOM TEMPERATURE HC2 °C X
 HEATING CURVE HC1
 GRADIENT HC1
13
0
5
0.4
0.2 for under-
floor heating
system
 LOW END HC1 14 °C 0 20 3 5
 ROOM INFLUENCE HC1 15 0 100 0