value
UNSCHED. VENT TIME STAGE 1 45 min 0 1000 60
UNSCHED. VENT TIME STAGE 2 44 min 0 1000 60
UNSCHED. VENT TIME STAGE 3 43 min 0 1000 60
FLOW RATE
FAN STAGE VENT. AIR 1 37 m³/h 10 300 140
FAN STAGE VENT. AIR 2 38 m³/h 80 300 170
FAN STAGE VENT. AIR 3 39 m³/h 80 300 220
FAN STG. EXTRACT AIR 1 40 m³/h 10 300 140
FAN STG. EXTRACT AIR 2 41 m³/h 80 300 170
FAN STG. EXTRACT AIR 3 42 m³/h 80 300 220
PASSIVE COOLING
PASSIVE COOLING
OFF| EXTRACT AIR| SUP-
PLY AIR| BYPASS| SUM-
MER CASSETTE
75
OFF
PASS. COOL EXP. AIR OFF| ON OFF
AIR STOP SUMMER DHW OFF| ON OFF
HUMIDITY PROTECTION
HUMIDITY PROTECTION OFF| ON OFF
HUM. THRESHOLD VALUE % 30 70 55
HUMIDITY HYSTERESIS % 2 10 5
HUM. MASKING TIME min 1 10 3
SET HUMIDITY MIN % 30 60 50
OUTPUT REDUCTION % 0 50 0
SET HUMIDITY MAX % 60 90 60
OUTPUT INCREASE % 0 100 0
OVEN / FIREPLACE
OFF| N/O CONTACT OFF|
N/C CONTACT OFF| N/O
MONITORING| N/C MONI-
TORING
OFF
AIR/AIR HE
MAX DEFROST DUR. min 60 250 60
DEFR START THRESHOLD 0 50 20
FILTER SPEED 0 100 20
SERVICE
RUNTIME FILTER d X 0 1024
RESET FILTER OFF| ON OFF
COOLING
ROOM TEMPERATURES HC1
ROOM TEMPERATURE DAY HC1 °C 10 30 25
ROOM TEMP. NIGHT HC1 °C 10 30 25
ROOM TEMP. STANDBY HC1 °C 10 30 30
ROOM TEMPERATURE HC1 °C X
ROOM TEMPERATURES HC2
ROOM TEMPERATURE DAY HC2 °C 10 30 25
ROOM TEMP. NIGHT HC2 °C 10 30 25
ROOM TEMP. STANDBY HC2 °C 10 30 30
ROOM TEMPERATURE HC2 °C X
COOLING MODE HC1
COOLING MODE HC1 OFF| ON OFF OFF
COOLING SYSTEM HC1 AREA COOLING| FAN
COOLING
AREA COOLING
HC TEMP. COOLING HC1 °C 10 25 18
HYST. ROOM TEMP. HC1 K 0.5 3 0.5
COOLING MODE HC2
COOLING MODE HC2 OFF| ON OFF OFF
COOLING SYSTEM HC2 AREA COOLING| FAN
COOLING
AREA COOLING
HC TEMP. COOLING HC2 °C 10 25 18
HYST. ROOM TEMP. HC2 K 0.5 3 0.5
STANDARD SETTING
HYST. FLOW TEMP. K 0.5 5 1.5
SOLAR
SOLAR ACTIVATION OFF| ON 80 OFF
TEMP. DIFFERENTIAL 81 K 2 15 8