INSTALLATION
Settings
20 | VRC-W 400 (E) www.stiebel-eltron.com
12.1.1 "Info" menu
Info
Value
 Bypass status Off | On
 Extract air temp. °C
 Extract air hum. %
 Extract air dew pt °C
 Outdoor air temp. °C
 Outdoor air hum. %
 Outdoor air dew pt °C
 Supply air temp. °C
 Exhaust air temp. °C
 Supply air fan control %
 Supply air fan speed rpm
 Supply air flow rate m³/h
 Exhaust air fan control %
 Exhaust air fan speed rpm
 Exhaust air flow rate m³/h
 Heating coil control %
 Extract air diff. press. Pa
12.1.2 "Diagnostics" menu
Diagnostics
Value
 Notification list
 Clear notification list Off | On
 Filter runtime h
 Filter reset Off | On
 Filter change interval d
 Device operating time d
 Fan operating time d
Diagnostics
 Clear notification list
To clear the notification list, set this parameter to "On". Press "OK"
to confirm. Afterwards, "Off" is displayed again and the fault mes-
sages are deleted.
12.1.3 "Programs" menu
Programs
Value
 Fan program
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Monday - Friday
Saturday - Sunday
Monday - Sunday
12.1.4 "Settings" menu
Settings
Value
 View Code for qualified con-
tractor
 General
 Time/date Day
Hour:Minute
 Language
German
English
Francais
Nederlands
Italiano
Polski
Cesky
Magyar
Slovensko
中文
Slovensky
日本
 Contrast 1 - 10
 Brightness %
 Touch sensitivity 1 - 10
 Touch boost
 Prog. unit software
 Fan control
 Constant flow rate
 Constant pressure
 Air flow rate
 Flow rate, stage0 m³/h
 Flow rate, stage1 m³/h
 Flow rate, stage2 m³/h
 Flow rate, stage3 m³/h
 Supply air flow rate offset m³/h
 Extract air diff. press.
 Diff. pressure, stage 0 Pa
 Diff. pressure, stage 1 Pa
 Diff. pressure, stage 2 Pa
 Diff. pressure, stage 3 Pa
 Favourites F1, F2, F3
 F1
F2
F3
Bypass status
Extract air temp.
Extract air hum.
Filter runtime
Device software version
Device software patch
Term. device serial no.
 Humidity prot. Only for qualified con-
tractors
 Enable humidity control (A2)
Off
On
 Humidity prot. interval h
 Humidity threshold %
 Humidity capture delay min
 Intensive ventilation
 Intens. vent. time min
 Heat recovery bypass
 Set room temperature °C
 Operating mode heat recovery bypass
Disabled
Bypass/window contact
Outdoor air routing au-
tomatic
Extract air routing autom.
 Temperature to enable heat recovery by-
pass
°C
 Temperature to block heat recovery bypass °C
 Hysteresis for heat recovery bypass K
 Temp. differential for heat recovery bypass K
 Window contact mode (A2)
(depending on unit)
Without window contact
With window contact
 Cooling/heating, heat recovery bypass
Cooling/heating
Cooling
Heating
 Frost protection Only for qualified con-
tractors
 Frost protection temp. °C
 Temp. to enable frost protection (A2) °C
344462-45598-9853_VRC-W_400_E_en_fr_it_nl.indb 20344462-45598-9853_VRC-W_400_E_en_fr_it_nl.indb 20 07.07.2023 17:00:1807.07.2023 17:00:18