EasyManuals Logo

STIEBEL ELTRON WPL 10 A Installation Instructions

STIEBEL ELTRON WPL 10 A
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
3
Heat pump
Part no.
Type WPL 10 A
22 08 12
WPL 10 I
22 08 11
WPL 10 IK
22 08 26
Design and operating mode compact compact compact
Design: compact / split / open version mono-mode
altn. dual-mode
parallel dual-mode
mono-mode
altn. dual-mode
parallel dual-mode
mono-mode
altn. dual-mode
parallel dual-mode
Dimensions, weights, connection dimensions
Dimensions
Weight
L/W/H
mm
kg
1122 x 967 x 1245
182
856 x 758 x 1010
166
925 x 778 x 1668
212
Refrigerant Type R 407C
Fill weight kg see type plate
Pipe connector – heating side (flow and return)
“/mm
G 1¼” (male) 22 plug-in conn. 22 plug-in conn.
Air hose connector (inlet and outlet connector) L/W mm 152 x 407 oval hose Ø 315
Expansion vessel volume
primary pressurek
l
MPa (bar)
12
0.15 (1.5)
Output
Heat output at A–7/W35
1)
at A2/W35
2)
kW
kW
5.4
6.7
5.4
6.7
5.4
6.7
Power consumption at A–7/W35
1)
at A2/W35
2)
kW
kW
1.8
2.1
1.8
2.1
1.8
2.1
Performance factor at A–7/W35
1)
at A2/W35
2)
2.9
3.3
2.9
3.3
2.9
3.3
Power consumption – booster heater kW 8.8 8.8 8.8
Process medium
Volume flow, hot side WNA nominal / min
4)
m³/h 1.4 /0.5 1.4 / 0.5 1.4 / 0.5
Internal pressure differential hPa 195 195 195
Volume flow, cold side WQA min 3
3)
m³/h 1200 1200 1200
Externally available static pressure differential (only for internal version) hPa 1,0 1,0
Operating temperature limits
WQA min. / WQA max
3)
°C – 20 (– 10) / + 30 – 20 (– 10) / + 30 – 20 (– 10) / + 30
WNA min. / WNA max
4)
°C + 15 / + 50 (+ 60) + 15 / + 50 (+ 60) + 15 / + 50 (+ 60)
Electrical specification
Fuses:
Heat pump power supply (compressor)
Supply – booster heater DHC (internal HS 2)
Control circuit
A
A
A
16 gl
16 gl
16 gl
16 gl
16 gl
16 g
l
16 gl
16 gl
16 gl
Protection EN 60529 (DIN VDE 0470) IP 14 B IP 20 IP 20
Voltage / frequency – compressor V/Hz 3/N/PE~400/50 3/N/PE~400/50 3/N/PE~400/50
Voltage / frequency – booster heater DHC (internal HS 2) V/Hz 3/N/PE~400/50 3/N/PE~400/50 3/N/PE~400/50
Voltage / frequency – control circuit V/Hz 1/N/PE~230/50 1/N/PE~230/50 1/N/PE~230/50
Starting current A < 25 < 25 < 25
Defrost
Time/demand/manual defrost demand / manual demand / manual demand / manual
Type of defrost: hot gas/electric/air/flow reversal flow reversal flow reversal flow reversal
Heating the drip pan yes, supercooler yes, supercooler yes, supercooler
Other model characteristics
Frost protection measures
yes/no
yes yes yes
Corrosion protection – frame and casing hot-dipped galv. hot-dipped galv. hot-dipped galv.
Compliant with safety regulations DIN EN 60335; DIN 8975,
EMC Directive 89/336/EEC,
Low Voltage Directive 73/23/EEC
Sound power level to DIN EN 255
Sound pressure level at 5 m
External installation Internal installa-
tion; internal / external
dB(A)
dB(A)
dB(A)
65
43
57/62
35/41
57/62
35/41
1)
A–7/W35 = Air inlet temperature: -7 °C, heating flow: 35 °C
2)
A2/W35 = Air inlet temperature: 2 °C, heating flow: 35 °C
3)
WQA = Heat source system (cold side)
4)
WNA = Heat utilisation system (hot side)
2 Specification (check details on the type plate)
2.1 Specification triplephase(equipment information)

Other manuals for STIEBEL ELTRON WPL 10 A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STIEBEL ELTRON WPL 10 A and is the answer not in the manual?

STIEBEL ELTRON WPL 10 A Specifications

General IconGeneral
BrandSTIEBEL ELTRON
ModelWPL 10 A
CategoryHeat Pump
LanguageEnglish

Related product manuals