Edition Manual Chapter Page
2014-09-23 Workshop Manual, GGP Park 7 Electrical System 5
Valid for (Art. Number)
1005-0072
13-6101-19 - - -
Fault Cause/Alternative Action
The engine can be started
with the mower deck activated.
Adjust or replace the mover deck switch.
The engine can be started
with a gear activated.
Adjust or replace the gear switch.
The engine does not stop
when the operator leaves the
seat and the mover deck is
activated.
The engine can be stopped with
the ignition key.
1. Adjust or replace the seat switch
2. Adjust/replace the mover deck switch.
The engine can not be stopped
with the ignition key.
Replace the ignition switch.
The engine does not stop
1. Check the white cable and its
connection to the engine.
2. Replace the ignition switch.
The starter does not rotate and
there is no “click” heard at the
start attempt.
Fault in the safety circuits. 1. Adjust/replace the mover deck switch.
2. Adjust or replace the gear switch.
3. Replace the safety relay.
4. Replace the ignition switch.
5. Replace the start relay.
The starter does not rotate and
there is a “click” heard at the
start attempt.
Faulty start engine or start relay 1. Check cable connections.
2. Replace the start relay.
3. Replace the start engine
The starter rotate, but the
engine does not start.
1. Check the fuel supply.
2. Check the engine according to
the engine manual.
3. Check that the white short circuit cable
is not connected to earth.
4. Replace the ignition switch.
5. Replace the shut off valve.
The battery runs repeatedly
empty.
A connected voltmeter to the
battery shows a higher voltage at
high speed than if the engine not is
running.
Replace the battery.
No voltage different. 1. Check engine socket connections.
2. Replace the ignition switch.
3. Replace the voltage regulator.
4. Replace the alternator.