EasyManua.ls Logo

Stiga TRE 0702 - Replacing the Coil

Stiga TRE 0702
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Release 00 - 03/2018
pag. 32
Engine TRE 0701-TRE 0702-TRE 0801
Service manual
7 - Perform a spark test as indicated in [ 9.1].
- If the spark jumps: the coil functions properly and
in the event of malfunction, verify that the cut-off
cable (12) is not earthed.
- if the spark does not jump: the coil is faulty and
must be replaced [ 9.3].
8 - Close the fan nut to the indicated couple and
reassemble the cowl [ 6.1].
9.3. Replacing the coil
1 - Remove the cowl and the fan [
6.1].
2 - Disconnect the faston of the earth cable (6).
3 - Unscrew the screws (9) and remove the coil
(7).
4 - Mount the new coil and regulate the air gap
according to the procedure indicated in points 4
and 5 in section [ 9.2].
5 - Connect the faston of the earth cable (6).
6 - Ret the fan and close the nut to the indicated
couple and the cowl [ 6.1].
Tightening torques
1 Spark plug tightening torque 18-22 Nm
9 Coil xing screws 8-12 Nm
Technical information
Type of spark plug
RN12YC (Champion) or equivalent
Distance between electrodes 0,6-0,8 mm
Air gap/ywheel 0,25-0,40 mm
Special equipment
3 Tester for spark test