109TS 500i
: Pull the hose (1) into the tank
housing with the tab (2) until the
hose completely encloses the
opening (arrow)
Cut off the tab (2)
Fitting an existing hose
Use STIHL press fluid to simplify
assembly, b 13
: Position the tank housing (1) on
the crankcase from below
: Lay a piece of string (approx.
30 cm) around the hose (2)
(single loop) and guide the ends
of the string through the opening
(arrow) in the tank housing (1)
Hold the tank housing in place
1307RA232 TG
1
2
1307RA233 TG
2
1
: Pull the hose (1) into the tank
housing with the ends of the
string (2) until the hose
completely encloses the opening
(arrow)
Remove the string
Bearing plug (1) must be twisted
into the antivibration spring as far as
it will go.
: Push the tank housing with
bearing plug (1) into the mount
(arrow) and hold it in position
: Screw in the screw (1) and
tighten it
1307RA234 TG
1
2
1307RA331 TG
1
1307RA235 TG
1
: Push the manifold (1) completely
and evenly onto the
supports (arrow) of the tank
housing until it is in the groove on
the circumference
Push the hose clip over the
shoulder of the manifold
: Align the hose clip (1) on the
manifold (3) so that the clamping
gap lines up with the fin (arrow)
: Screw in the screw (2) and
tighten it
1307RA236 TG
1
1307RA237 TG
1
2
3