22
AFTER SALES SUPPORT
1300 886 649
info@tempo.org
AUS
MODEL: STR-BGC PRODUCT CODE: 60165 06/2018
Installation (Cont.)
Commissioning process
The below process must be performed on the gas cooktop by the authorised
plumber/gastter before leaving:
Conrm that the supplied gas regulator is correct.
Turn on and light the rapid burner only to check operation.
Measure and conrm the test point pressure is correct.
Make any adjustment, change, modication or repair required due to
inadequate performance of the cooktop.
Final installation checks
After commissioning and before leaving, the installer must check and ensure
that:
All parts (burners, trivets, knobs) and the gas pipe are installed correctly.
The ignition system is working satisfactorily on all burners, both individually
and combined.
When lit, each burner produces a well dened blue ame without any
yellow tipping.
Each burner ame remains lit when the respective control knob is rotated
quickly from the HIGH to the LOW position.
The duplicate data label provided with this appliance is attached to an
accessible and nearby surface for easy reference.
There are no leaks in the gas supply. We recommend conducting a
full gas soundness check according to the requirements of AS/NZS
5601. Whenever any change to the installation is made that may affect
gas soundness (e.g., adjustments involving any disconnection and
reconnection), follow the below leak test procedure. Never use a naked
flame to check for gas leaks!
In a small container, mix up a solution of water and detergent or soap.
Make sure that the gas supply is turned on and all gas control valves on
the appliance are off. Using a brush or spray bottle, apply the solution to
the gas line and each joint in the gas line, including any exible hosing and
regulator. Bubbling of the solution will indicate that there is a leak present.
Retighten or reseal any joints that are leaking. If the leak persists, contact
our after sales support centre for assistance.