STOBER 5 | Technical data
03/2020 | ID 442793.03
23
Nominal currents up to +45°C (in the control cabinet)
Electrical data SC6A062
f
PWM,PU
4kHz
I
1N,PU
10A
I
2N,PU
2×4.5A
I
2maxPU
210% for 2s
Tab. 15: SC6 electrical data, size 0, for 4kHz clock frequency
Electrical data SC6A062
f
PWM,PU
8 kHz
I
1N,PU
8.9A
I
2N,PU
2×4A
I
2maxPU
250% for 2s
Tab. 16: SC6 electrical data, size 0, for 8kHz clock frequency
Electrical data SC6A062
U
onCH
780–800 V
DC
U
offCH
740–760V
DC
R
2minRB
100Ω
P
maxRB
6.4kW
P
effRB
2.9kW
Tab. 17: Brake chopper electrical data, size 0