Where to store the nebulizer
1. Make sure that the battery is fully charged.
2. Make sure that the power is off.
3. Store the nebulizer in a cool and dry environment with a room temperature from ranging
between 15° and 35° C.
4. If the nebulizer will not be used for a long time, charge the battery at least once every six
months.
5. The nebulizer and the battery charger must be stored safely, protected from heat, dust and
moisture.
6. The nebulizer and flammable substances must be kept at least 1.5 meters apart.
7. Do not turn on the power switch during storage.
Storage
The most important thing to keep in mind before storing your nebulizer is to make sure that the
battery is fully charged and the power is off.
Troubleshooting
Please contact your local retailer or Stocker S.r.l. for assistance and service
Problem Cause Solution
The nebulizer does not
spray even if the motor
is running
1. The filter is clogged
2. Faulty motor
3. The delivery tube
between the tank and
motor is crushed
1. Remove the filter from the tank
and rinse it thoroughly
2./3. Send it for repair to an
authorized local retailer or to
Stocker Srl
The motor does not run
even with the nebulizer
switched on (the LED
above the start key is
lit red)
1. Some wires have come
loose
2. Faulty motor
3. The pressure is too
high or too low
4. The tank is empty
5. The spraying intervals
are set incorrectly.
1./2. Send it for repair to an
authorized local retailer or to
Stocker Srl
3. Check the error message on the
display and check that the nozzles
are fitted correctly.
4. Fill the tank
5. Check programming of the
intervals
The nebulizer does not
start (the LED above the
start key is off)
1. The battery is dead
2. Faulty battery
3. Faulty PCB/display
4. Some wires have come
loose
1. Charge the battery
2. Replace the battery
3./4. Send it for repair to an
authorized local retailer or to
Stocker Srl
The display is not
working
1. Faulty PCB/display
2. The battery is dead
3. Faulty battery
4. Some wires have come
loose
1./4. Send it for repair to an
authorized local retailer or to
Stocker Srl
2. Charge the battery
3. Replace the battery
Internal mixing does not
start
1. The nozzle is clogged
2. Faulty valves
3. The delivery pipe
between the nozzle,
valves and motor is
clogged
1. Remove the nozzle from inside
the tank and rinse it thoroughly,
removing any debris
2./3. Send for repair to an
authorized local retailer or to
Stocker Srl
The keys do not work 1. Faulty PCB
1. Send it for repair to an
authorized local retailer or to
Stocker Srl
Cleaning and maintenance
The nebulizer must be cleaned after each cycle to prevent the liquids used from causing
corrosion and blocking of the nozzles.