- 19 -
MAINTENANCE
RP652
Before commencing work on any electrical
equipment, disconnect the battery and cover
it with insulating materials.
Do not confuse PLUS and MINUS poles
on the battery.
It is essential that short-circuits be prevented
in cables carrying currents.
Burnt-out light bulbs in indicator lamps
should be replaced immediately.
When cleaning the machine with a high-
pressure water jet, do not spray the electrical
components directly.
After washing the components, blow-dry
them with compressed air in order to prevent
surface leakage current and corrosion.
MAINTENANCE WORK (HONDA ENGINE)
Attention - Only the maintenance work that has to be
performed daily is included in this operating manual.
Please refer to the Engine Operating Manual and to
the maintenance instructions and intervals listed
therein.
FILLING UP WITH FUEL
FILL FUEL TANK ONLY WHEN ENGINE IS
SWITCHED OFF. NO NAKED FLAMES. NO
SMOKING. NEVER FILL FUEL TANK IN
ENCLOSED AREAS.
1. Clean the area around the fuel filling socket.
2. Open the cap and check the fuel level
visually.
3. If necessary, fill up with unleaded fuel.
CHECKING THE ENGINE OIL LEVEL
1. Park the machine horizontally.
2. Clean the area around the oil filler cap.
3. Open the oil filler cap.
4. Check the oil level and refill up to the edge
of the oil filler cap if necessary.
5. Check the seal on the dipstick and replace if
necessary.
6. Close the oil filler cap.
7. Allow the engine to run for approximately
one minute and check oil level again with
engine switched off.
Oil
SAE 10W40
API SG-CE
WARNING