d2: Defrosting temperature limit
This permits to terminate defrosting when the adjusted desired temperature value is reached. The
defrosting time set with "d3" nevertheless runs at the same time, i.e. it functions as safety net to
terminate the defrosting process in case the defrosting temperature is not reached.
d3: Defrosting time limit
After the here set time the defrosting process is terminated.