46
Be careful not to touch the muffler while it is hot.
Let the engine cool before storing the generator indoors.
The engine exhaust system will be heated during operation and remain hot immediately after stopping the engine.
To prevent scalding, pay attention to the warning marks attached to the generator.
Connections for standby power to a buildings electrical system must be made by a qualified electrician and must comply with all
applicable laws and electrical codes. Improper connections can allow electrical current from the generator to back feed into the utility
lines. Such back feed may electrocute utility company workers or others who contact the lines during a power outage, and when utility
power is restored, the generator may explode, burn, or cause fires in the building’s electrical system.
Always make a pre-operation inspection before you start the engine. You may prevent accident or equipment
damage.
Place the generator at least 1m(3ft) away from buildings or other equipment during operation.
Operate the generator on a level surface. If the generator is tiled, fuel spillage may result.
Know how to stop the generator quickly and understand operation of all the controls. Never permit anyone to
operate the generator without proper instructions.
Keep children and pets away from the generator when it is in operation.
Keep away from rotating parts while the generator is running.
Keep away from cigarette, smoke and sparks when refueling the generator.
Always refuel in a well-ventilated location.
Gasoline is extremely flammable and explosive under certain condition.
Refuel in a well-ventilated area with the engine stopped.
Wipe up spilled gasoline at once.
The generator is a potential source of electrical shocks when misused; do not operate with wet hands.
Do not operate the generator in rain or snow and do not let it get wet.
You MUST unplug any load from the generator before starting and stopping to prevent permanent damage to any
appliances.
The installation and major repair work shall be carried out only by specifically trained personnel.
Engine exhaust gases are toxic. The generator set is only used outdoors.
protection against electrical shock depends on circuit breakers specially matched to the generating set. The circuit breakers must be
replaced with the one having idential ratings and performance characteristics.
Due to high mechanical stresses only tough rubber sheathed flexible cable or the equivalent should be used.
when using extension lines or mobile distribution networks the total length of lines for a cross section of 1.5mm2 should not exceed
60m;for a cross section of 2.5mm2 this should not exceed 100m.
15
Unpacking
Due to modern mass production techniques, it is unlikely that your StrongLine Power Tool is faulty or that a part is missing. If you find
anything wrong, do not operate the tool until the parts have been replaced or the fault has been rectified. Failure to do so could result in
serious personal injury.