Page 47
Wine Storage
Wine Storage
(400-
(400-
2
2
)
)
Series
Series
Electronic Control System
3-31
#3758410 - Revision C - May, 2014
Monitor Compressor Run Duration, Displays If Service is Needed
The microprocessor observes the state of the compressor relay to determine the length of compressor run time (See
Figure 3-57). If the compressor runs 100% (4 hours), an error code is logged (EC 50), and defrost will be initiated,
but SERVICE will not
flash.
If several 100% compressor run periods occur, and a drawer is not opened during the last excessive compressor run
period, and the temperature in the zone is not able to fall half way between set-point and low off-set, then SERVICE
will flash (See Figure 3-58).
NOTE: To clear an error code, the problem must be corrected, then the Alarm ON/OFF key pressed for fifteen (15)
seconds. Failure to clear an error code will cause SERVICE to display constant.
NOTE: If the unit is ever switched OFF then immediately back ON, the compressor will not energize for at least 3
minutes. This 3 minute minimum OFF time is used to protect the compressor and its electricals.
Figure 3-58. Service Flashing if several 100% compressor run periods occurred, a drawer was not opened
during last excessive run period, and temperature is not able to fall half way between set point & low off-set.
UNIT
REFRIGERATOR
ON/OFF
ON/OFF
WARMERCOLDER
SERVICE
Figure 3-57. Signal Trace Schematic - Compressor Run
115 VOLTS
60 CYCLES
HIGH VOLTAGE
L1
STARTING RELAY
COMPRESSOR
COMPRESSOR
PROTECTOR
OVERLOAD
NEUT
31
564
DPDT RELAY
BOARD
MAIN
BLACK
PURPLE
BLUE
WHITE
NEUTRAL WHITE
NEUTRAL WHITE
RED
PURPLE
ORANGE
BLACK
RED
YELLOW
LOWER DRAWER LIGHTS
CONDENSER FAN MOTOR
EVAPORATOR FAN MOTOR
TOP DRAWER LIGHTS
M
M
2000 Ω
MULLION HEATER
NEUTRAL WHITE
M
ORANGE
ORANGE
DOOR SWITCH
DOOR SWITCH
P4
J5
J4
J6
J3
P2
P1
P3
J2
Compressor relay closed, allowing 115 Volts AC to
compressor. This is observe by microprocessor.