Content
Con-
nector
No.
Termi-
nal No.
Signal (V)
Note
Ignition SW ON
(Engine OFF)
Engine ON (Idling)
Mass air
flow sensor
Signal B84 13 — 0.3 — 4.5 —
Shield B84 8 0 0 —
GND B84 7 0 0 —
Intake air temperature
sensor signal
B135 27 —— —
Exhaust
gas tem-
perature
sensor
Signal B135 16 —— —
GND
(sensor)
B135 19 0 0 —
Tumble
generator
valve posi-
tion sensor
RH
Signal B84 23
Fully closed: 0.2 — 1.0
Fully opened: 4.2 — 4.7
—
Power sup-
ply
B135 9 5 5 —
GND
(sensor)
B135 19 0 0 —
Tumble
generator
valve posi-
tion sensor
LH
Signal B84 13
Fully closed: 0.2 — 1.0
Fully opened: 4.2 — 4.7
—
Power sup-
ply
B135 9 5 5 —
GND
(sensor)
B135 19 0 0 —
Tumble generator valve
RH (open)
B84 4 0 or 5 0 or 5 —
Tumble generator valve
RH (close)
B84 5 0 or 5 0 or 5 —
Tumble generator valve
LH (open)
B84 11 0or5 0or5 —
Tumble generator valve
LH (close)
B84 10 0or5 0or5 —
Wastegate control sole-
noid valve
B137 24 10 — 13 13 — 14 —
Starter switch B134 16 0 0 Cranking: 8 — 14
A/C switch B134 6
ON: 10 — 13
OFF: 0
ON: 13 — 14
OFF: 0
—
Ignition switch B134 14 10 — 13 13 — 14 —
Neutral
position
switch
MT B135 8
ON: 12±0.5
OFF: 0
Switch is ON when gear is in
neutral position.
AT B135 8
ON: 0
OFF: 12±0.5
Switch is ON when shift is in
“N” or “P” position.
Test mode connector B134 5 5 5 When connected: 0
Knock sen-
sor
Signal B135 4 2.8 2.8 —
Shield B135 22 0 0 —
Back-up power supply B137 10 10 — 13 13 — 14 Ignition switch “OFF”:10— 13
Control unit power sup-
ply
B137 2 10 — 13 13 — 14 —
B137 3 10 — 13 13 — 14 —
Sensor power supply B135 9 5 5 —
Line end check 1 B134 10 0 0 —
Ignition
control
#1 B136 24 0 13 — 14 Waveform
#2 B136 23 0 13 — 14 Waveform
#3 B136 22 0 13 — 14 Waveform
#4 B136 21 0 13 — 14 Waveform
EN(DOHC TURBO)-27
ENGINE CONTROL MODULE (ECM) I/O SIGNAL
Engine (Diagnostics)