Model WS-30 Installation 32
Electrical Requirements
F
or model WS-30, the electrical supply should be located
within the shaded area shown in the illustration. Follow the
National Electrical Code and local codes and ordinances
when installing the receptacle. A separate circuit, servicing
only this appliance is required.
IMPORTANT NOTE: A ground fault circuit interrupter
(GFCI) is not recommended and may cause interruption of
operation.
Electrical Requirements
Power Supply 115 V AC, 60 Hz
Circuit Breaker 15 amp
Receptacle 3-prong grounding-type
75
1
/2"
(1918)
7"
(178)
6
"
(
152)
E
FRONT VIEW
Location of electrical supply.
The outlet must be checked by a qualified electrician
to be sure that it is wired with the correct polarity.
Verify that the outlet provides 115 V AC and is
properly grounded.
Do not use an extension cord or two-prong adapter.
Electrical ground is required on this appliance. Do
not remove the power supply cord ground prong.