1800-3000 USER MANUAL SECTION 3
26
3.3 APPLICATION GUIDE
Sullair encourages the user to participate in a fluid
analysis program with the fluid suppliers. This could
result in a fluid change interval differing from that
stated in the manual. Contact your Sullair dealer for
details.
3.4 LUBRICATION CHANGE RECOMMENDATIONS AND
MAINTENANCE—FLUID FILTER AND SEPARATOR
LUBRICANT FLUID CHANGE FLUID FILTER CHANGE SEPARATOR CHANGE
Sullube (2.5 gal) A, E G, C A, D
SRF 1/4000 (2.5 gal) B, E G, C B, D
24KT (2.5 gal) F, E G, C A, D
CP-4600-32-F (2.5 gal) B, E G, C B, D
A. 8,000 hours or once a year.
B. 4,000 hours or more frequently if conditions so require.
C. When measured pressure loss exceeds 20 psig (1.3 bar).
D. When measured pressure loss exceeds 10 psig (0.7 bar).
E. When required by fluid analysis or known contamination.
F. Does not require replacement during normal service conditions.
G. Every 2,000 hours.