Section 3
SPECIFICATIONS
13
SULLAIR SERIES 32 SPECIFICATIONS
DIMENSIONS
COOLING MODEL SERIES LENGTH WIDTH HEIGHT WEIGHT
in
mm in mm in kg lb kg
Water 32---400HP 198 5029 96 2489 82 2083 14100 6396
Water 32---450HP 198 5029 96 2489 82 2083 14100 6396
Air 32---400HP 198 5029 96 2489 82 2083 13700 6214
Air 32---450HP 198 5029 96 2489 82 2083 13700 6214
A i r --- C o o l e d M o d u l e 46 1168 64 1626 88 2235 1500 680
COMPRESSOR: STANDARD MODELS
Type Rotary Screw
Standard Operating Pressure (I) 110 PSIG (758kPa) (L), Unload Pressure
125 PSIG (862kPa) (H) Unload Pressure (II)
Bearing Type Anti---Friction
Ambient Temperature (Max.) (III) 105_F(41_C)
Cooling Pressurized Fluid
Lubricant Sullube 32
Sump Capacity 70 Gallons (265 Liters)
Control Electro---Pneumatic
MOTOR:
STANDARD MODELS
Size 400 and 450HP
Type Open Dripproof, 460V, AC, Three Phase,
60 Cycles, 40_C Maximum Ambient Temperature
Options Available: 575V, 2300V, 4160V
TEFC Also Available
Speed 1770 RPM
(I) Special compressors are available for operating at higher pressures.
(II) Maximum full load pressure (L) = 100 PSIG (689kPa) (H) = 115 PSIG (793kPa).
(III) Special compressors are available for operation in higher ambient temperatures.