SECTION 3 600H, 700HH, 750, 750H, 750HH, 825, 900H, 1050 USER MANUAL
65
3.2 TABLE OF SPECIFICATIONS—825, 900H, 1050
3.3 LUBRICATION GUIDE—COMPRESSOR
Table 3-5: Overall Dimensional Specifications—825, 900H, 1050
Model Series
Length (I) Width Height (II) Weight (wet) Weight (dry)
in mm in mm in mm lb kg lb kg
DTQ (Tandem) 241 6121 88 2235 103 2616 16810 7625 14991 6800
DLQ (LRG) 189 4801 88 2235 70 1778 15230 6908 13411 6083
(l) Length including drawbar where applicable
(II) Over lifting bail
Table 3-6: Compressor Specifications
Compressor 825 900/1050 900H
Type Rotary Screw Rotary Screw Rotary Screw
Delivery @ Operating Pressure 825 900/1050 900H
Maximum Operating Pressure 125 psig (8.6 bar) 125 psig (8.6 bar) 150 psig (10.3 bar)
Rated Pressure 125 psig (8.6 bar) 100 psig (6.9 bar) 150 psig (10.3 bar)
Cooling
Pressurized Compressor
Fluid
Pressurized Compressor
Fluid
Pressurized Compressor
Fluid
Lubricating Compressor Fluid
See Lubrication Guide,
Engine on page 66
See Lubrication Guide,
Engine on page 66
See Lubrication Guide,
Engine on page 66
Hydraulic Tank Capacity 13 gal 13 gal 13 gal
Receiver Tank Capacity 20 gal 20 gal 20 gal
Operating Tilt (maximum) 15° 15° 15°
Electrical System
Engine – 24 Volt Engine – 24 Volt Engine – 24 Volt
Instrument System – 24
Volt
Instrument System – 24
Volt
Instrument System – 24
Volt
Battery (2)
1150 CCA @
0°F (-18°C)
1150 CCA @
0°F (-18°C)
1150 CCA @
0°F (-18°C)
Alternator 95A 95A 95A
Sound Level (US EPA)
1
76dBA 76dBA 76dBA
Sound Level (CE)
2
72dBA 72dBA 72dBA
1 Sound level measured per U.S. 40 CFR Ch. 1 Part 204
2 Sound level measured per 2000/14/EC Outdoor Noise Directive
Fluid Type Change Period, Hours Ambient Temperature Range °F (°C)
Sullair AWF (I) 1500 -20 to 120 (-29 to 49)
D-A Torque Fluid 300 10 to 110 (-12 to 43)
SAE 10W DSE, SF, SG, CD 300 0 to 100 (-18 to 38)
MIL-L-2104E 10W 300 0 to 100 (-18 to 38)
Sullair T4 Hydraulic Fan Fluid (II) Annual -20 to 125 (-29 to 52)
(I) Sullair part numbers for multi-viscosity lubricants are 250030-757 (5 gallons/18.9 liters), 250030-758 (55 gallons, 208
liter drum)
(II) Requirements for other fluids:
—Must meet Park Hannifan HF-0
—Maximum viscosity for cold weather operation: 1600 cSt at minimum ambient temperature
—Minimum viscosity at 225°F (107°C) 6cSt