SECTION 5 DE-18 USER MANUAL
67
P-62
C267 CM Fail
(0=disabled)
0-1000 Sec 120
P-63
C277 CM Fail
(0=disabled)
0-1000 Sec 120
P-64
MAX PRS@
Only change pressure mode when
the engine is not running. Change
the “setup lockout (S-7) to “YES”.
(135 PSI mode or 150 PSI mode
selected press enter key once, to
confirm change.)
When a change is confirmed the
unit will do a factory default with
the new pressure mode defaults
and then it will reboot. The reboot
will automatically reset the “setup
lockout (S-7) to “NO”.
135 PSI / 150 PSI
P-65
MAX PRS@
Only change pressure mode when
the engine is not running. Change
the “setup lockout (S-7) to “YES”.
(135 PSI mode or 150 PSI mode
selected press enter key once, to
confirm change.)
When a change is confirmed the
unit will do a factory default with
the new pressure mode defaults
and then it will reboot. The reboot
will automatically reset the “setup
lockout (S-7) to “NO”.
-1-3000 MIN 0 min
P-66
UNLATCH PRS
(Used only when sequencing
multiple units.) Once the unit
exceeds the setpoint pressure +
the unload pressure, the unit is
latched in stop mode. If the
pressure drops below the unlatch
pressure a unit will be started.
75-135 PSI 90 PSI
“P” Number Description Range Default Setting