DHL HEATLESS REGENERATIVE DRYER SECTION 3
14
3.3 INSTALLATION LAYOUT
Dryer is supplied with 0.01 micron filter on
the inlet and a 1 micron filter on the outlet.
Type A installation is suggested when the
compressed air treated from the dryer is only a part
of the total flow rate of the compressor; or when the
compressor operates at reduced intermittence and
the total consumption equals the compressor flow
rate.
Figure 3-1: Recommended Installation
Table 3-1: Correction Factor for inlet Pressure
PSIG
50 60 70 80 90 100 110 120 130 140 150 175 200 225 250
BAR
3.5 4.1 4.8 5.5 6.2 6.9 7.6 8.3 9.0 9.7 10.3 12.1 13.8 15.5 17.3
F1 Factor
0.56 0.65 0.74 0.83 0.91 1.0 1.06 1.08 1.12 1.16 1.2 1.29 1.37 1.45 1.52
Table 3-2: Correction factor for Inlet Temperature
°F
70 80 90 100 105 110 115 120
°C
21 27 32 38 40 43 46 49
F2 Factor
1.12 1.09 1.06 1.0 0.93 0.86 0.80 0.75