EasyManua.ls Logo

Sullair ES-11 SERIES - Lubrication Guide; Lubricant Change Recommendations and Maintenance

Sullair ES-11 SERIES
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 3
SPECIFICATIONS
10
FLUID FILTER
T ype: Spin on, Sullair Proprietary
Micron: 23 Microns Abs.
Internal Bypass Valve Set at 25 psig (1.7 bar)
FLUID SEPARATOR ELEMENT
T ype: Push In Cartridge, Sullair Proprietary
Efficiency at Maximum Capacity: 4PPM Maximum
3.2 LUBRICATION GUIDE
For best value and longest uninterrupted service,
the ES--11 compressor is factory filled and tested
with a long life lubricant.
If, due to availability or other reasons, other fluids
are required, follow Lubrication Guide below.
W ARNING
!
“The Plastic Pipe Institute recommends against
the use of thermoplastic pipe to transport com-
pressed air or other compressed gases in exposed
above ground locations, e.g. in exposed plant pip-
ing.” (I)
Sullube 32 should not be used with PVC piping
systems. It may affect the bond at cemented joints.
Certain other plastic materials may also be af-
fected.
(I) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.
Maintenance of all other components is still recom-
mended as indicated in the Operator’s Manual.
For light--duty high--humidity service where con-
densed moisture and emulsification (mayonnaise)
may occur, the fluid change interval must be re-
duced to 300 hours maximum. A non--detergent
fluid with rust, oxidation and foam inhibitors and
good water separation characteristics should be
used.
DO NOT MIX DIFFERENT TYPES OF FLUIDS.
Contamination of non--detergent mineral fluids with
traces of detergent motor fluids may lead to opera-
tional problems such as foaming, filter plugging, ori-
fice or line plugging.
NOTE
Flush system when switching lubricant brands.
When ambient conditions exceed those noted or if
conditions warrant use of extended” life lubricants
contact Sullair for recommendation.
Sullair encourages the user to participate in a fluid
analysis program. This could result in a fluid change
interval that is different from those stated in this
manual.
3.3 LUBRICANT CHANGE RECOMMENDATIONS AND MAINTENANCE
LUBRICANT
FLUID CHANGE
Sullube 32
A,E A,C A,D
Sullair LLL--4--32
A,E A,C A,D
SRF 1/4000
B,E B,C B,D
24KT
F,E A,C A,D
CP-4600-32-F
B,E B,C B,D
SEPARATOR CHANGE
B--
4,000 Hours or more frequently if conditions so require.
FLUID FILTER CHANGE
C--
When measured pressure loss exceeds 20 psig (1.3 bar)
D--
When measured pressure loss exceeds 10 psig (.7 bar)
E--
When required by fluid analysis or known contamination
F--
Does not require replacement during normal service conditions
A--
8,000 Hours or once a year.

Table of Contents

Related product manuals