SECTION 3 ES-6 USER MANUAL
55
3.20 ID, WIRING DIAGRAM—SRS 25-100 115-230V/1/60
NOTES:
1. BY INSTALLER -
OF RESIDUAL CURRENT AUTOMATIC CIRCUIT BREAKER
ELECTRICAL SPECIFICATIONS
COMPRESSOR - UN 115V 1PH 60HZ FAN MOTOR - UN 115V 1PH 50-60HZ
SRS-25 FLA 4.32 0.41KW FLA 0.46 0.035KW
SRS-35 FLA 4.32 0.41KW FLA 0.46 0.035KW
SRS-50 FLA 7.31 0.651KW FLA 1.00 0.076KW
SRS-75 FLA 9.23 0.809KW FLA 1.00 0.076KW
SRS-100 FLA 11.44 1.082KW FLA 1.00 0.076KW
COMPRESSOR - UN 23-V 1PH 60HZ FAN MOTOR - UN230V 1PH 50-60HZ
SRS-100 FLA 5.72 1.082 KW FLA 0.50 0.076KW
ELECTRICAL SUPPLY LINE
1 PHASE + NEUTRAL + PROTECTION EARTH
CABLES SIZE
3G16AWG
COMPONENT DESCRIPTION
QS MAIN SWITCH
CN ELECTRIC DRAIN POWER SUPPLY
MC COMPRESSOR MOTOR
EV FAN MOTOR
SK COMPRESSOR OVERLOAD PROTECTOR
KA STARTING RELAY
C COMPRESSOR START CAPACITOR
TV FAN THERMOSTATIC SWITCH
HT HIGH TEMPERATURE SAFETY SWITCH