separation away from the metal flanges - if any
faults are found, elements must be replaced and
Sullair contacted for further assistance.
4. Reassemble in reverse order. Capscrews must
be re-torqued to 30 ft.-lbs. (40.7Nm) (dry).
Please note that capscrews have self-locking
patches good for two re-uses, but the applica-
tion of a thread-locking adhesive increases this
number.
Please note that replacement of either shaft hub
requires the removal of the motor, an operation best
handled by Sullair personnel.
Section 7
MAINTENANCE
41
Figure 7-7 Drive Coupling Alignment (I)
(I) Alignment data is shown for reference only. The C-face motor mounting arrangement does not require adjust-
ment for coupling alignment.
(II) Angular mis-alignment in inches equals maximum A minus minimum B. DO NOT exceed values in Table 7-1
Installation Data.
TABLE 7-1 INSTALLATION DATA
Max. Operating Misalignment
Tightening Coupling Coupling Capscrew
Torque Gap Parallel Angular
in.-lbs. +0.30 in./7.6mm Offset
T.I.R. (II) degrees in./mm (II)
360 1.50 .005 .5 .005
40.7Nm 38mm .127mm .5 .127mm
DO NOT lubricate capscrew threads.