Correction factor for operating pressure modifications:
Correction factor for ambient temperature modifications:
Correction factor for inlet air temperature modifications:
Correction factor for DewPoint modifications:
Calculation of the actual air throughput:
Actual air throughput = air throughput acc. to planning x factor (F1) x factor (F2) x factor (F3) x factor (F4)
The SR 75 has a planned nominal capacity of 75 scfm (127 m³/h). The highest achievable air mass under the
following operating conditions is:
Air inlet pressure = 120 psig (8 barg)
Ambient temperature = 105°F (40°C)
Air inlet temperature = 122°F (50°C)
Pressure dew point = 50°F (10°C)
Factor (F1) = 1.07
Factor (F2) = 0.93
Factor (F3) = 0.65
Factor (F4) = 1.25
Every function parameter corresponds to a numerical factor which, multiplied by the planned nominal capacity,
determines the following: