10.4.2 Resetting the Alarm History
1) Press the Alarm Reset & Alarm Report buttons simultaneously to access the User Parameter
Menu. The display will show you are at Parameter A1”.
2) Press the Down button repeatedly to scroll down to ParameterB7.
3) Press Enter to access this parameter. The display will show you it’s value is “no”.
(The value cannot be changed by pressing the Up or Down buttons.)
4) Press the Up & Enter buttons simultaneously for 5 seconds. The value will change to “Yes” for
a moment and then change back to no”. The alarm has now been reset.
5) Press Exit to exit the parameter. The display will show you are at Parameter “B7”.
6) Press Exit again to exit the User Parameter Menu. The display will show the dewpoint if the dryer
is on, “OFF” if the dryer is off, or rOF” if the dryer is in Remote Off Mode.
Please Note:
The purpose of the Alarm History Report warning is to provide critical information to service personnel
when troubleshooting the unit.
For this reason, the
p
rocedure presented below is intended
ONLY for authorized factory and distributor service technicians.
&
&