12. Maintenance Procedures
12.1 Replacing a Pressure Switch
When removing any pressure switch (High Pressure Switch [3.3.7],
Low Pressure Switch [3.3.8] or Fan Pressure Switch [3.3.9]) use
two spanners to avoid cracking the weld on the T joint.
Use a copper gasket to guarantee a seal.
Place the gasket inside the switch connection
with a drop of oil or grease to keep it in
position while screwing the switch onto the
valve.
12.2 Replacing the Drain Valve
Loosen the 3 piece union.
Unscrew the electrical connector.
Remove the fixing nut.
Remove the old coil and install the new one.
Replace the fixing nut.
Reattach the electrical connector.
Tighten the 3 piece union.
12.3 Cleaning the Condensate Strainer
The internal strainer of the drain valve should be cleaned at
least every four to six months.
Unscrew the cap at the bottom side of the drain valve.
Remove the strainer.
Clean the strainer with compressed air.
Replace the strainer.
Tighten the cap firmly, but do not over-tighten.