Section 3
SPECIFICATIONS
19
3.1 SULLAIR SERIES TS-32S SPECIFICATIONS
60 Hz MODEL LENGTH WIDTH HEIGHT (I) WEIGHT
(IN) (IN) (IN) (LB)
(AC) 175 84 93 (II)
(WC) 175 84 93 (II)
50Hz MODEL LENGTH WIDTH HEIGHT (I) WEIGHT
(CM) (CM) (CM) (KG)
(AC) 444.5 213 218 (III)
(WC) 444.5 213 218 (III)
(I) Add 1 in./2.5 cm for enclosure. Add 37 in./94 cm (200-350hp/149-261kw) for servicing the separator.
(II) Add 1,040 lbs./ 472 kg for air-cooled enclosure package.
(III) Add 1,800 lbs./ 816 kg for water-cooled enclosure package.
For noise level information, please contact the Sullair Factory Service Department.
COMPRESSOR:
Type: Positive displacement, fluid-lubricated, twin rotary screws
Standard Operating Pressure: 400, 500 and 600hp/ 298, 373 and 447kw
Bearing Type: Anti-friction
Ambient Temperature (Max.): 104ºF/40ºC; consult factory for higher ambient temperatures
Lubricant: See Sections 3.2 and 3.3 on Lubricant
Coolant: Pressurized Sullube
Fluid Capacity: 48 gallons/ 181.7 liters
Control Type: Electro-pneumatic
Options: Cold Weather Package, EES Remote Heat Recovery,
Enclosure, Phase Monitor Relay, Remote Cooler Pack- Air-
cooled, Water Solenoid Valve, Water Regulator Valve
MOT
OR:
Size: 400-600hp/ 298-447kw- Consult factory for specific voltages
Type: Open Dripproof enclosure, 3-phase, 60 Cycles
104ºF / 40ºC Maximum Ambient Temperature
Options: Various voltages, TEFC enclosure: CE approved, Motor-OPD
Premium Efficient, Motor- ODP Standard Efficient -3300V
Speed: 1780 RPM (60Hz), 1475 RPM (50Hz)
Starter: Full-voltage, Wye-delta, or Solid State; various voltages
3.2 LUBRICATION GUIDE- STANDARD COMPRES-
SORS
Refer to Figure 3-1. Sullair TS-32S Series standard
compressors are filled with Sullube fluid as factory
fill.
Mixing of other lubricants within the compres-
sor unit will void all warranties.
Sullube fluid should be changed every 8000 hours
or once a year, whichever comes first. The fluid
should be changed more frequently under severe
operating conditions, such as high ambient temper-
atures coupled with high humidity, or when high
particulate level, corrosive gases or strong oxidizing
gases are present in the air.
Maintenance of all other components is still recom-
mended as indicated in the Maintenance section of
this manual.