Section 8
MAINTENANCE
50
To replace the fluid filter element, follow these
steps:
1. Using a strap wrench, remove the old element
and gasket.
2. Clean gasket seating surface.
3. Apply a light film of fluid to the new gasket.
4. Hand tighten new element until new gasket is
seated in the gasket groove. Avoid any nicks,
cuts or pinches to the gasket.
5. Continue tightening element by hand an addi-
tional 1/2 to 3/4 turn.
6. Restart compressor and check for leaks.
AIR FILTER MAINTENANCE
Air filter maintenance should be performed when
indicated by the maintenance display/gauge when
running full load, or once a year, whichever comes
first. If the filter needs to be replaced, order replace-
ment element. Following you will find procedures
on how to replace the air filter element.
AIR FILTER ELEMENT REPLACEMENT
Refer to Figure 8-2.
1. Clean exterior of air filter housing.
2. Unscrew the wing nut securing the cover.
3. Unscrew the wingnut assembly securing the pri-
mary element in place.
4. Carefully remove the element from the housing.
5. Replace with new element, making sure that it
rests correctly in position.
6. Replace the wingnut assembly and tighten to
secure element in place.
7. Replace the cover.
8. Secure the cover by tightening the wingnut.
SEPARATOR MAINTENANCE
Replace the separator elements when indicated by
the maintenance display/gauge or after one (1)
year, whichever comes first.
Figure 8-2 Air Filter Replacement (P/N 02250059-096)
*Replacement Element P/N 02250145-731
To minimize the possibility of separator element
rupture, it is important that ONLY replacement
elements identified with the Sullair name, logo
and appropriate part number be used and that
substituted elements not be used, due to the fact
that such elements may have inadequate or
questionable working pressure ratings.
Relieve all pressure from the sump tank and all
compressor lines.
To ensure proper filter ratings vital for system
cleanliness it is important that ONLY a replace-
ment fluid filter identified with the Sullair name,
logo and appropriate part number be used, and
that substituted filters not be used, due to the
fact that such filters may have inadequate or
questionable ratings.

Table of Contents