Section 3
SPECIFICATIONS
19
3.1 TABLE OF SPECIFICATIONS
Model Series Length Width Height (I) Weight (II)
in mm in mm in mm lb kg
LS-200S - 125HP/90KW 100 2540 60 1524 66.5 1690 4660 2114
LS-200S - 150HP/110KW 100 2540 60 1524 66.5 1690 4980 2259
(I) An additional height of 25in/ 63.5cm is needed to service the separator element.
(II) Weight listed is for an open package. Add 590 lbs./268 kg. to weight and 1.5 in./38 mm to height for enclo-
sure package.
COMPRESSOR:
Type: Positive displacement, fluid-lubricated, twin rotary screws
Configuration: Single-stage geared integral drive
Bearing Type: Anti-friction
Lubricant: Pressurized Sullube
Coolant: See Sections 3.2, 3.3 and
3.4 on Lubrication
Sump Fluid Capacity: 9 gallons (34 liters)
System Fluid Capacity: 14 gallons (53 liters)
Duty Press: 100-110 psig (6.9-7.6 bar)
Control Type: Electro-pneumatic
Options: Higher duty pressures up to 175 psig (12.1 bar),
spiral valve, 24KT lubricant
MOTOR (60Hz):
Size: 125-150HP/90-110KW, 4-pole speed
Service: 3 ph, 60 Hz, 460 VAC, 40ºC ambient
Type: ODP enclosure, NEMA frames 405TSC through 445TSC
Options: TEFC enclosure, various voltages
MOTOR (50Hz):
Size: 125-150HP/90-110KW, 1500 RPM
Service: 3 ph, 50 Hz, 400 VAC, 40ºC ambient
Type: ODP enclosure, NEMA frames 405TSC through 445TSC
Options: IP23, TEFC enclosure, various voltages
Noise levels vary with machine and enclosure. For machine dBA output,
consult factory with machine serial number.
3.2 LUBRICATION GUIDE- STANDARD COMPRES-
SORS
Refer to Figure 3-1. Sullube fluid should be
changed every 8000 hours or once a year, whichev-
er comes first. The fluid should be changed more
frequently under severe operating conditions, such
as high ambient temperatures coupled with high
humidity, or when high particulate level, corrosive
gases or strong oxidizing gases are present in the
air.
Sullair standard compressors are filled with
Sullube fluid as factory fill.
Mixing of other lubricants within the compressor
unit will void all warranties.
“The Plastic Pipe Institute recommends against
the use of thermoplastic pipe to transport com-
pressed air or other compressed gases in
exposed above ground locations, e.g. in exposed
plant piping.” (I)
PVC piping should not be used with Sullube. It
may affect the bond at cemented joints. Certain
other plastic materials may also be affected.
(I) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.
Before changing or recharging system fluid
always relieve all pressure from the sump tank
and all compressor lines.

Table of Contents