Section 3
SPECIFICATIONS
20
Maintenance of all other components is still recom-
mended as indicated in the Operator's Manual.
Sullair encourages the user to participate in a fluid
analysis program with the fluid suppliers. This could
result in a fluid change interval differing from that
stated in the manual. Contact your Sullair dealer for
details.
3.3 LUBRICATION GUIDE- 24KT COMPRESSORS
Refer to Figure 3-1. Sullair 24KT compressors are
filled with a lubricant which rarely needs to be
changed. In the event a change of fluid is required,
use only Sullair 24KT fluid.
Sullair recommends that a 24KT sample be taken at
the first filter change and sent to the factory for
analysis. This is a free service. A sample kit with
instructions and self-addressed container is to be
supplied by your Sullair Representative at start-up.
The user will receive an analysis report with recom-
mendations.
3.4 LUBRICATION GUIDE- OPTIONAL FLUID
Refer to Figure 3-1. Sullair compressors may use
SRF 1/4000 fluid as an optional factory fill.
SRF 1/4000 fluid should be changed every 4000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under
severe operating conditions, such as high ambient
temperatures coupled with high humidity, or when
high particulate level, corrosive gases or strong oxi-
dizing gases are present in the air.
For extended life synthetic lubricants contact the
nearest Sullair representative.
Maintenance of all other components is still recom-
mended as indicated in the Operator's Manual.
Figure 3-1 Fluid Fill Port
DO NOT mix different types of fluids.
MIXING OF OTHER LUBRICANTS WITHIN THE
COMPRESSOR UNIT WILL VOID ALL WAR-
RANTIES.
Flush system when switching lubricant brands.
DO NOT mix different types of fluids.
MIXING OF OTHER LUBRICANTS WITHIN THE
COMPRESSOR UNIT WILL VOID ALL WAR-
RANTIES.
Flush system when switching lubricant brands.
Before changing or recharging system fluid
always relieve all pressure from the sump tank
and all compressor lines.
Before changing or recharging system fluid
always relieve all pressure from the sump tank
and all compressor lines.
When performing a fluid
change or topping off the
fill, the proper level should
be at half of the sight glass,
with the machine off.