Section 3
SPECIFICATIONS
17
VACUUM PUMP:
Type : Lubricated Rotary Screw
Maximum Operating Vacuum (I): 29.5 in-Hg. (750mm) - sea level
Maximum Ambient Operating
Temperature (I) : 105ºF (40ºC)
Maximum Inlet Gas Temperature : 200ºF (93ºC)
Bearing Type : Anti-Friction
Cooling : Pressurized Fluid
Lubricant : SRF 1/4000 or Sullube
Sump Capacity (30, 40HP / 22, 30KW) : 10 Gallons ( 37.9 Liters)
Sump Capacity (50HP / 37KW) : 15 Gallons ( 56.8 Liters)
Control : Vacuum
(I) Special machines are available for operation in higher and lower ambient temperatures. For tempera-
tures less than 60ºF (15.6ºC) ambient, consult factory.
3.1 SPECIFICATIONS - VS-16 30-50HP / 22-37KW
MODEL
SERIES
LENGTH WIDTH (I) HEIGHT (II) WEIGHT
IN MM IN MM IN MM AIR-COOLED WATER-COOLED
LB KG LB KG
VS16
30HP: Open
75.75 1924 48.00 1219 62.25 1518 2260 1025 2255 1023
VS16
30HP: Encl
78.00 1981 48.00 1219 62.25 1518 2655 1204 2650 1202
VS16
40HP: Open
75.75 1924 48.00 1219 62.25 1518 2260 1025 2255 1023
VS16
40HP: Encl
78.00 1981 48.00 1219 62.25 1518 2655 1204 2650 1202
VS16
50HP: Open
80.63 2048 48.00 1219 63.75 1518 2660 1207 2525 1145
VS16
50HP: Encl
82.88 2105 48.00 1219 63.75 1518 3090 1402 2690 1220
For latest sound test data, consult Sullair factory.
(I) Add 30.13” with inlet filter mounted.
(II) Add 24.00” (30-40HP/22-30KW), 22.44 (50HP/37KW) additional height for servicing the separator