15
The doors will
not close
properly.
The appliance is not properly leveled.
The gaskets are dirty.
The shelves are out of position.
Level the appliance with the
adjustable feet.
Clean the door gaskets.
Check the shelves and refit correctly.
Display “E0”,
“E1”. “E2”,
“E3”, “E4”,
“E5” or “E7”.
E0indicates a communication error for
3-zone models.
E1or E2indicates that the air
temperature sensor has failed.
E3or E4indicates that the defrost
sensor in the evaporator has failed.
E5indicates defrost heater failure.
E7indicates door switch failure.
Call for service.
The alarm
sounds and
the
temperature
display
flashes.
Has an appliance door been open for
longer than 60 seconds? If not, then the
temperature has risen higher or fallen
lower than the temperature that has been
set. This could be due to:
The appliance doors being opened too
often.
The ventilation opening being covered
or too dusty.
A lengthy interruption to the power
supply.
A large number of bottles have been
added to the unit.
If yes, close the door.
Do not open the doors more often
than necessary.
Clear the obstructions and remove the
dust.
Leave the appliance to work for a
while until the set temperature has
been reached.
The icon “--”
is lit up and
flashing in the
temperature
display.
The display temperature is out of range.
Only temperatures within the range
0~99°F/-9~37°C can be displayed. If
the temperature is not within this
range, the icon “-- will be displayed
instead. This is normal.

Related product manuals