SX1819TV: Parts Breakdown & Operating Manual Rev. 1/7/20
© Copyright 2020, Sunex Tools
®
Operating Instructions • Warning Information • Parts Break down
SX1819TV
3/16" AND 1/4" HEAVY DUTY
VACUUM RIVET GUN
Rivet Capacity ...........................
3/16" & 1/4"
Traction Power................................. 3,960 lbf.
Stroke Length ...........................................3/4"
Air Inlet ............................................. 1/4" NPT
Air Supply Hose Size .........................3/8" I.D.
Working Air Pressure ... 70-100 psig (6.2 bar)
Height .................................................... 12
9
16"
Weight ................................................... 5.7 lb.
SPECIFICATIONS
Some dust created by power sanding, sawing, grinding, drilling, and other
construction activities contains chemicals known to cause cancer, birth
defects or other reproductive harm. Some examples of these chemicals are:
lead from lead-based paints,
crystalline silica from bricks and cement and other masonry products, and
arsenic and chromium from chemically-treated lumber.
Your risk from these exposures varies, depending on how often you do this
type of work. To reduce your exposure to these chemicals: work in a well
ventilated area, and work with approved safety equipment, such as those
dust masks that are specially designed to filter out microscopic particles.
WARNING
WARNING
ALWAYS READ THIS MANUAL BEFORE OPERATING TOOL
ALWAYS WEAR EYE PROTECTION (USERS AND
BYSTANDERS) WHEN OPERATING OR PERFORMING
MAINTENANCE ON THIS TOOL
ALWAYS WEAR HEARING PROTECTION WHEN OPERATING
THIS TOOL (USERS AND BYSTANDERS)
ALWAYS WEAR FACE PROTECTION WHEN OPERATING THIS
TOOL (USERS AND BYSTANDERS)
AVOID PROLONGED EXPOSURE TO VIBRATION
Question and Answer IconNeed help?

Do you have a question about the Sunex SX1819TV and is the answer not in the manual?

Sunex SX1819TV Specifications

General IconGeneral
BrandSunex
ModelSX1819TV
CategoryRivet Tools
LanguageEnglish

Summary

General Safety Warnings

Read and Understand Manual

Emphasizes reading and understanding all instructions before operating the tool to prevent injury.

Operating and Maintenance Standards

Tool operation and maintenance must comply with ANSI B186.1 and other applicable safety codes.

Air Pressure and Hose Specifications

Operate at 90 psig with a 3/8" ID hose for optimal performance, durability, and safety.

Personal Protective Equipment

Always wear eye, face, and hearing protection when operating or performing maintenance.

Tool Handling and Condition

Ensure the tool is in efficient operating condition and operators are physically able to handle it.

Air Pressure Hazards

Never direct pressurized air at yourself or others; disconnect air supply before maintenance.

Vibration and Repetitive Motion

Discontinue use if discomfort from vibration occurs and seek medical advice.

Safe Work Practices

Maintain balance, avoid overreaching, and do not point tool or engage in horseplay.

Tool Operation Precautions

Be alert for motion changes, protect hoses, avoid contact with hot accessories, and keep clear of trigger.

Specific Tool Usage Restrictions

Do not modify the tool, use in explosive atmospheres, or exceed 100 psig air pressure.

Maintenance and Inspection

Inspect hydraulic section, ensure parts are secure, and follow proper maintenance procedures.

Chemical Exposure Warning

Product may expose users to chemicals like nickel, known to cause cancer and reproductive harm.

Air Supply and Lubrication

Air Supply Requirements

Recommends 90 psig clean, dry air with a 3/8" ID hose. Avoid dust, fumes, and water.

Lubrication Procedure

Lubricate air motor daily with air tool oil. Oil may discharge from exhaust after lubrication.

Tool Operation

Pre-Operation Safety

Turn off air supply, drain pressure, and detach tool before any part installation or maintenance.

Operating Mechanism

Describes how lever/trigger activation moves piston, fluid, and jaws to set the rivet.

Post-Operation Release

Explains throttle valve reset, air exhaust, and return spring action upon lever release.

Servicing Procedures

Nosepiece Replacement

Change nosepieces with the tool connected to air, holding the lever, using the maintenance tool.

Jaw Cleaning and Replacement

Clean jaws with solvent or brush; replace if worn. Apply oil to sliding surfaces during reassembly.

Jaw Opening Adjustment

Adjust head for proper jaw distance to ensure rivet mandrel can be removed and inserted freely.

Troubleshooting

Rivet Gripped, Not Set/Broken

Check air pressure, fittings, and call for service if malfunction persists.

Mandrel Fit or Ejection Issues

Address jaw distance, dirty/damaged jaws, or fatigued springs. Check for air leaks.

Multiple Strokes for Rivet Setting

Verify air pressure, nosepiece fit/size, and rivet body length for proper operation.

Limited Warranty

Warranty Coverage

One-year warranty covers defects in workmanship and materials; repair or replacement provided.

Warranty Exclusions

Excludes damage from alteration, abuse, misuse, or unauthorized repairs; no consequential damages.

Warranty Service Procedure

Return equipment with proof of purchase and defect description to Sunex Tools or authorized center.

Related product manuals