Safety and Installation Instructions
for Europe, Asia, Australia, Latin America and Africa
This document applies to Maxeon and Performance PV Modules
Languages:
English
French
German
Italian
Spanish
Polish
Indonesian
Contents of this manual are subject to change without notice.
In case of inconsistencies or conflicts between the English version and any other versions of this manual (or
document), the English version shall prevail and take control in all respects.
For the latest Europe, Asia, Australia, Latin America and Africa please refer to
www.sunpower.maxeon.com/int/PVInstallGuideIEC
Maxeon Solar Technologies, Ltd.
www.sunpower.maxeon.com
Document 001-15497 Rev AA
P/N 100657
REVISION:
AA
English French German Italian Indonesian
Spanish
Polish
Question and Answer IconNeed help?

Do you have a question about the SunPower X Series and is the answer not in the manual?

SunPower X Series Specifications

General IconGeneral
TypeMonocrystalline
ManufacturerSunPower
Power OutputUp to 400 W
EfficiencyUp to 22.8%
Temperature Coefficient-0.29%/°C
Warranty25 years
Weight19 kg
ModelX22

Summary

1.0 Introduction

1.2 Conformity to International Electrotechnical Commission (IEC) standards

Product meets IEC standards for PV modules for building installation.

1.3 Limited Warranty

Module limited warranties are described in the Maxeon warranty document.

2.0 Safety Precautions

3.0 Electrical Characteristics

4.0 Electrical Connections

4.1 System & Equipment Grounding

Refer to regional and local codes for grounding PV arrays and mounting frames.

4.2 Series Connection

Modules may be wired in series to produce the desired voltage output.

4.3 Parallel Connection

Modules may be combined in parallel to produce the desired current output.

5.0 Module Mounting

5.1 Site Considerations

Modules must be mounted in locations meeting specific temperature and shading requirements.

Performance Series Mounting Orientation

Performance Series modules designed for landscape orientation for better shading and soiling performance.

5.2 Mounting Configurations

Mounting system must provide a flat plane and not cause stress on modules.

5.3 Ground Mount Applications for Bifacial modules

Environmental and installation parameters affect bifacial gain, such as albedo and irradiance.

5.4 Rooftop Applications for Bifacial modules

Bifacial modules use reflected sunlight; recommended for flat roof applications.

5.5 Bifacial Electrical Considerations

Overall bifacial gain determined by albedo, irradiance, tilt angle, shading, and elevation.

5.6 Handling of Modules during Installation

Avoid abrasive surfaces, protect from liquids, use gloves for AR glass, do not lift by cables.

Recommended Cable Management